Attention please! Here is the shortcut to pass your HCE-3700 exam! Get yourself well prepared for the Architect-Expert HCE-3700 Hitachi Vantara Certified Expert – Performance architect exam is really a hard job. But don’t worry! We We, provides the most update HCE-3700 actual tests. With We latest HCE-3700 new questions, you’ll pass the Architect-Expert HCE-3700 Hitachi Vantara Certified Expert – Performance architect exam in an easy way
Visit our site to get more HCE-3700 Q and As:https://www.leads4pass.com/hce-3700.html (60 QAs Dumps)
Question 1:
You are evaluating storage system performance for an interactive workload. What are three appropriate criteria in this situation? (Choose three.)
A. customer requirements
B. throughput (MBs)
C. elapsed time
D. storage system response time
E. resource utilization (% busy)
Correct Answer: BCD
Question 2:
A 10K RPM Small Form Factor 600 GB disk drive has a 3 ms average rotational latency and a 4 ms average seek time.
How many random read IOPS would you expect from a 4D 4D RAID group using these drives before any consideration for cache hits or queuing optimization benefits?
A. approximately 570 IOPS
B. approximately 1,140 IOPS
C. approximately 1,530 IOPS
D. approximately 2,280 IOPS
Correct Answer: D
Question 3:
In a VSP G200 system, what are two advantages of RAID 1 0 compared to RAID 5/6 for random write workloads? (Choose two.)
A. RAID 1 0 provides more useable capacity per for the same number of drives.
B. RAID 1 0 has less processing overhead.
C. Disk virtualization is lower.
D. RAID 1 0 has more efficient pre-fetch operation.
Correct Answer: AC
Question 4:
Which three functions are performed by a VSP G1000 Virtual Storage Director (VSD)? (Choose three.)
A. It executes host I/O requests.
B. It calculates parity.
C. It manages cache segment usage.
D. It moves data to/from cache.
E. It executes software such as HDP or copy products.
Correct Answer: ACD
Question 5:
Which two statements are true about the Active Flash feature on the VSP Midrange? (Choose two.)
A. The Active Flash feature of Hitachi Dynamic Tiering monitors page access frequency in real-time, and immediately promotes pages that suddenly become busy.
B. The Active Flash feature can be enabled on any HDT pool as long as Tier 1 of the Dynamic Tiering pool is composed of SSD or FMD drives.
C. The Active Flash feature can be enabled on any HDP pool as long as the pool is comprised of SSD or FMD drives.
D. The Active Flash feature of Hitachi Dynamic Tiering monitors page access frequency in real-time, and promotes pages based on a predefined schedule.
Correct Answer: AB
References: https://knowledge.hitachivantara.com/Documents/Management_Software/SVOS/8.2/Volume_Management_-_VSP_G1x00,_F1500/Tiered_Storage/02_About_active_flash
Question 6:
Which two port options are bi-directional on a VSP G800? (Choose two.)
A. Replication-Target (RCU)
B. Open Target (TAR)
C. External Target (eLUN)
D. Mainframe (FICON)
Correct Answer: AB
References: https://knowledge.hitachivantara.com/Documents/Management_Software/Configuration_Manager_REST_API/8.5.2/REST_API/Volume_allocation
Question 7:
You are partitioning a VSP G1000 with eight VSDs and 1024 GB cache, and are creating an 80 GB CLPR.
In this scenario, how much cache does each VSD blade initially reference in the CLPR?
A. 10 GB
B. 80 GB
C. 640 GB
D. 1024 GB
Correct Answer: D
References: https://support.hitachivantara.com/download/epcra/rd80124.pdf
Question 8:
You are sizing a VSP G4000 for a customer who requires good performance but has a very limited budget. You now must select a cache size between 64 GB and 128 GB.
Which three conditions will affect your selection in this situation? (Choose three.)
A. The customer plans to use Cache Logical Partitions (CLPRs)
B. The customer environment is mainly VMware.
C. The number of LDEVs that are available.
D. The customer will use ShadowImage.
E. The number of connected hosts.
Correct Answer: ACE
Question 9:
You are designing a VSP G1000 solution for a customer and you need to determine the appropriate disk type and RAID level.
What information do you need to design the solution? (Choose three.)
A. type of workloads
B. workloads read-write ratio
C. operating systems used in the environment
D. fan-in and fan-out ratios
E. expected I/O rates
Correct Answer: ABE
Question 10:
Which two statements are true regarding HDP pools? (Choose two.)
A. Using the largest possible pools is a recommended practice.
B. Exposure to failure and recovery from failure must be considered when recommending the maximum size of a pool.
C. HDP pools can be used for sizing HDT pools.
D. Tier migration is based on performance and space capacity.
Correct Answer: AC
Question 11:
A customer has several Oracle databases with different workload profiles residing on old HUS systems. The customer wants to consolidate workloads on a new VSP G800 system to increase database performance and to reduce costs. Which configuration would you use to accomplish this task?
A. Put all of the databases in a single HDT pool.
B. Put each database in its own HDT pool.
C. Put databases with the same workload profile together in their own HDT pool.
D. Put all database tablespaces and indexes in the first HDT pool, all redo logs in the second HDT pool, and all undo logs in a third HDT pool.
Correct Answer: A
Question 12:
Your VSP G1000 customer has an HDP pool with 600 GB drives and they need more IOPS in the pool. Which action will satisfy the requirement?
A. Spread the pool over storage tiers.
B. Add 1.2 TB drives to the pool.
C. Add more 600 Gb drives of the same type.
D. Create a new HDP pool.
Correct Answer: A
Question 13:
Immediately after migrating to a new HDT pool, Hitachi Tuning Manager shows that Tier 1 SSD, Tier 2 SAS, and Tier 3 NL-SAS are not busy for performance but Tier 1 and Tier 2 are over utilized for capacity. From this analysis, which action should be performed?
A. Re-asses after HDT performs page migration cycles.
B. Add more drives to Tier 1.
C. Add more drives to Tier 1 and Tier 2.
D. Remove the SSD tier.
Correct Answer: C
Question 14:
Relocation cycles are regulatory failing to complete in an HDT implementation where the customer is also reporting lower than expected performance. What should be done in this scenario?
A. Change to Continuous mode and increase the monitor period cycle time.
B. Change to Period mode and increase the monitor period cycle time.
C. Change to Period mode and reduce the monitor period cycle time.
D. Change to High-Performance mode and reduce the monitor period cycle time.
Correct Answer: B
Question 15:
When testing an external LUN with default mapping on two paths, performance appears constrained and the utilization of the RAID group in the external storage system never exceeds 35% busy no matter how many test threads are generated. You want to increase the utilization of the external RAID group.
Which two actions will accomplish this task? (Choose two.)
A. Increase the external path LUN queue depth setting.
B. Increase the number of LUNs mapped from the external RAID group.
C. Change Cache Mode to “Disabled”.
D. Increase the server HBA LUN queue depth to 64.
Correct Answer: AC
Visit our site to get more HCE-3700 Q and As:https://www.leads4pass.com/hce-3700.html (60 QAs Dumps)